What are the Notes when using the Plalstic Flame Retardant ?
03 Nov 2023 - Flame Retardant,Plastic Flame Retardant,PP Flame Retardant,ABS Flame Retardant
What are the Notes when using the Plastic Flame Retardant ?
A: What are the Nots when using the Plastic Flame Retardant ?
B: This is a very Professinoal and wise question , Because to ensure succesfully reach the Flame retarancy Modification , there is really several important requirements for the Product Formula and even related to the final product thickness .
1. Requirement on product formula:
1). Due to that inorganic fillers like cac03 ,tio2 , talc ,glass fiber , baso4 , wax all effects the Flame Retardant performance , especially Caco3 , its better not to contain any caco3 in your product formula when you want to reach V0 by adding Flame retardant . Caco3 could even make the Flame retardant useless .
When your product formula cant aovid to use the tio2 , or talc , or glass fiber , or baso4 , or wax , its okay to add them , but meanwhile need to add higher dosage of Flame Retardant to keep the good Flame retardancy perforamance .
2). Must predry the Flame retardant with products all raw materials together to remove the moisture . because moisture will decrease the Flame Retardant Performance .
2. Final product thickness issue : Generally , the thinner the final product ,the high dosage of the flame retardant need to add to ensure good Flame Retardant .
3. The adverse effect when using Flame retardant : it decreases the Notch impact strength /toughness / flexibility .
So when choose the Flame Retardant, better to choose Flame retardant with less dosage , thus its adverse effect on impact strength /toughness /flexibility would be much less and even be ignored .
4 . Very Important:
1)we have PP Flame Retardant P-25 with only 3-6% dosage . so ensure not effect other physical properties
2) And Because ABS flame retardant dosage genearally high around 22%,. but because our ABS flame retardant already contains impact modifier inside , so even high dosage of ABS flame retardant ,it nearly no effect on other properties .
3) We have transparent impact modifier which could use with Flame retardant together and ensure not effect the Flame retardancy for customer who have both impact strength and flame retardancy modification requirement.
If have more inquiry or need samples to test , please feel free to contact :
CONTACT PERSON